Chauvet 4 Dmx Controller User Manual

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

DMX-4

Dimmer/Relay Pack

USER MANUAL

Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A (800) 762-1084 – (954) 929-1115

FAX (954) 929-5560 www.chauvetlighting.com

Table of Contents

Before You Begin..................................................................

3

What is included ....................................................................

3

Unpacking Instructions ...............................................................

3

AC Power .........................................................................

3

Safety Instructions ..................................................................

3

Introduction.......................................................................

4

Features ..........................................................................

4

DMX Channel Summary..............................................................

4

Product Overview...................................................................

4

Setup............................................................................

5

Power............................................................................

5

Mounting .........................................................................

5

Orientation........................................................................

5

Rigging...........................................................................

5

Operating Instructions..............................................................

6

Menu Navigation....................................................................

6

Operating Modes ...................................................................

6

Running in Chase Mode..............................................................

6

Select Pattern Chase ................................................................

6

Adjust the Speed ...................................................................

6

Adjust Intensity .....................................................................

6

Running in DMX Mode ...............................................................

7

Select DMX Mode & Set Starting Address.................................................

7

Optional Dimmer/Relay Setting.........................................................

7

DMX Control Channel Modes ..........................................................

7

Replacing a fuse ....................................................................

7

Appendix.........................................................................

8

DMX Primer.......................................................................

8

Fixture Linking .....................................................................

8

DMX Channel Values................................................................

9

Maintenance.......................................................................

9

Returns Procedure..................................................................

9

Claims ...........................................................................

9

General Troubleshooting.............................................................

10

Technical Specifications.............................................................

11

BEFORE YOU BEGIN

What is included

1 x DMX-4 Dimmer/Relay Pack

1 x Detachable power cord (IEC 60320 C-13)

1 x User manual

1 x Warranty Card

Unpacking Instructions

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box

and packing.

AC Power

Chauvet 4 dmx controller user manual free

The DMX-4 may except multiple voltages (100V-240V) without the need of a voltage selection switch. This applies to the electronics in the fixture. However, this will not change the voltage being supplied to the load.

Note: Load voltage will match input voltage.

To determine the power requirements for a particular fixture, see the label affixed to the back plate of

the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average

current draw under normal conditions. All fixtures must be powered directly off a switched circuit and

cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer

channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the

source voltage matches the fixture’s requirement. Check the fixture or device carefully to make sure

that if a voltage selection switch exists that it is set to the correct line voltage you will use.

Warning!

Verify that the power supplied to the DMX-4 matches the power to your load.

Safety Instructions

Please read these instructions carefully, which includes important information about the installation, usage and maintenance?

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.

Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture.

This product is intended for indoor use only!

To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating.

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.

Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source.

Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying handles.

Maximum ambient temperature is Ta: 40°. Do not operate fixture at temperatures higher than this.

In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.

Don’t connect the device to a dimmer pack.

Make sure power cord is never crimped or damaged. Never disconnect power cord by pulling or tugging on the cord.

Avoid direct eye exposure to lamp while it is on.

Caution!

There are no user serviceable parts inside the unit. Do not open the housing or

attempt any repairs yourself. In the unlikely event your unit may require service,

please contact CHAUVET.

INTRODUCTION

Features

4 channels DMX-512 dimmer/relay pack

2 Edison plugs per channel

Each channel can be set as either dimmer or relay Each channel can be set to any DMX address

16 user-selectable chase patterns Variable electronic dimmer (0-100%)

Adjustable speed control and dimming with or without DMX

DMX Channel Summary

CHANNEL

FUNCTION

1

Dimmer or Switch

2

Dimmer or Switch

3

Dimmer or Switch

4

Dimmer or Switch

Product Overview

Output

10 Amps 115V/Ch, 15A max load

5 Amps 230V/Ch, 10A max load

Button Reference

This is a quick reference of button functions and what they display.

Power Switch

On/Off switch

Power Input

Supplied with IEC 60320 C-14 receptacle for detachable power cord

Hanging Bracket

Six holes provide different positions for mounting a pipe clamp

LED Indicator

4 LED channel activity indicators

LED Segment

Displays current activity or function state

Menu Buttons

Displays current activity or function state

Fuses

DMX In

DMX Out

20mm Glass 10A 125V

Locking 3-pin XLR male

Locking 3-pin XLR

20mm Glass 6.3A 250V

socket

female socket

SETUP

Power

Your product is capable of operating on AC 100-240V. But, please be aware that your output voltage equals your input voltage. This means that if you have the DMX-4 plugged into 120V of power, then you will be sending 120V output to any fixture that you plug into one of the 8 outlets. Likewise, if you have the fixture plugged into 208v, then you will get 208V out from the 8 outlets.

To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart.

A fixture’s listed current rating is its average current draw under normal conditions.

All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.

Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.

All fixtures must be connected to circuits with a suitable Earth Ground.

Mounting

ORIENT AT ION

This fixture may be mounted in any safe position provided there is adequate room for ventilation.

RIGGING

It is important never to obstruct the fan or vents pathway. Mount the fixture using, a suitable “C” or “O” type clamp. Adjust the angle of the fixture by loosening both knobs and tilting the fixture. After finding the desired position, retighten both knobs.

When selecting installation location, take into consideration lamp replacement access and routine maintenance.

Safety cables should always be used.

Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation.

Figure 1 - Hanging Clamp

Note!

Clamp is sold separately.

OPERATING INSTRUCTIONS

Menu Navigation

MODE

P:01~16

CHASE Mode

MENU

MENU

A001 ~ A512

P:01 ~ P:16

DMX Addressing

Pattern Chase Select

CH:01 ~ CH:04

SP:01 ~ SP:99

Control Channel Mode

Chase Speed Select

S – oF / S – on

d000 ~ d100

Relay/Dimmer Switch

Dimmer Output Level

Operating Modes

The DMX-4 can be controlled using any universal DMX-512 controller. There are also 16 preset chase programs that a user can select for stand alone operation (Chase Mode).

Running in Chase Mode

Free

SELECT PATTERN CHASE

1)Press the MODE button until the display reads {P:nn}, where n represents a number between 01 and 16.

2)Press the (Button) and (Button) to increase or decrease values representing chase patterns.

ADJUST T HE SPEED

1)Press the MODE button until the display reads {P:nn}, where n represents a number between 01 and 16.

2)Press the MENU button until the display reads {SP:nn}, where n represents a number between 01 and 99.

3)Press the (Button) and (Button) to increase or decrease values until the desired speed is achieved.

ADJUST INT ENSITY

1)Press the MODE button until the display reads {P:nn}, where n represents a number between 01 and 16.

2)Press the MENU button until the display reads {dnnn}, where n represents a number between 000 and 100.

3)Press the (Button) and (Button) to increase or decrease values until the desired intensity is achieved.

Running in DMX Mode

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a 'start address' that can be set from 001 to 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 6 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap and notate the start address selected for future reference.

If this is your first time addressing a fixture using the DMX-512 control protocol than I suggest jumping to the Appendix Section and read the heading “DMX Primer”. It contains very useful information that will help you understand its use.

SELECT DMX MODE & SET ST ART ING ADDRESS

1)Press the MODE button until the display reads {Annn}, where n represents a number between 001 and 512.

2)Press the (Button) and (Button) to increase or decrease values until the desired DMX starting address is achieved.

OPT IONAL DIMMER/RELAY SETT ING

1)Press the MODE button until the display reads {Annn}, where n represents a number between 001 and 512.

2)Press the MENU button until the display reads {S-nn}, where nn represents either (oF) for switching off or (oN) for switching on.

3)Press the (Button) and (Button) to toggle between {S-oN} and {S-oF}.

DMX CONT ROL CHANNEL MODES

1)Press the MODE button until the display reads {Annn}, where n represents a number between

001and 512.

2)Press the MENU button until the display reads {CH:nn}, where n represents a number between

01and 04.

3)Press the (Button) and (Button) to increase or decrease values to select a desired channel output

SELECTION

BEHAVIOR

CH:01

DMX channel 1 will control outputs (1 through 4 combined)

CH:02

DMX channel 1 will control outputs (1 and 2 combined)

DMX channel 2 will control outputs (3 and 4 combined)

CH:04

DMX channels 1 through 4 will control outputs 1 through 4 respectively

Replacing a fuse

Disconnect the power cord before replacing a fuse and always replace with the same type fuse.

With a Philips head screwdriver unscrew the fuse holder until it can be entirely removed. Remove the damaged fuse from its holder and replace with exact same type fuse. Insert the fuse holder back in its place and reconnect power.

DMX-4 User Manual

7

APPENDIX

DMX Primer

There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation. In other words, the fixtures will be slaved together and all respond exactly the same.

DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)

FIXT URE LINKING

Six20dbg iron label manual download. Ibanez's beautiful Iron Label SIX20DBG 6-string solidbody electric guitar takes the speed and performance of their S series to a whole new level of intensity. Boasting a lightweight mahogany body and a top made of gorgeous figured bubinga, the SIX20DBG provides you with phenomenal resonance, epic sustain, and stunning good looks to match.

Figure 2 - DMX connector configuration

COMMON

1

DMX +

INPUT

3

2

DMX -

1Resistance 120 ohm 1/4w between

3

pin 2 (DMX -) and

2

pin 3 (DMX +) of

the last fixture.

1

3

OUTPUT

2

Termination reduces signal errors and to

avoid signal transmission problems and

interference, it is always advisable to connect

a DMX signal terminator.

Note!

If you use a controller with a 5 pin DMX output connector, you will need to use a 5

pin to 3 pin adapter. Chauvet Model No: DMX5M.

The chart below details a proper cable conversion:

3 PIN TO 5 PIN CONVERSION CHART

CONDUCTOR

3 Pin Female (output)

5 Pin Male (Input)

GROUND/SHIELD

Pin 1

Pin 1

DATA ( - )SIGNAL

Pin 2

Pin 2

DATA ( + ) SIGNAL

Pin 3

Braun series 7-760cc user manual. Pin 3

DO NOT USE

Do not use

DO NOT USE

Do not use

Chauvet Dmx 40 Controller Manual

DMX Channel Values

Function

Channel

Value

Dimmer or Switch

1

000 255

Off > Full Intensity/On

2

000 255

Off > Full Intensity/On

3

000 255

Off > Full Intensity/On

4

000 255

Off > Full Intensity/On

Maintenance

To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month.

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components.

Returns Procedure

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.

Claims

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.

General Troubleshooting

Applies to

Symptom

Solution(s)

Foggers

Dimmers

Lights

& Snow

Controllers

& Chaser

Auto shut off

Check fan thermal switch reset

Beam is very dim or not

Clean optical system or replace lamp

bright

Check 220/110v switch for proper setting

Breaker/Fuse keeps

Check total load placed on device

blowing

Chase is too slow

Check users manual for speed adjustment

Device has no power

Check for power on Mains.

Check device’s fuse. (internal and/or external)

Fixture is not responding

Check DMX Dip switch settings for correct addressing

Check DMX cables

Check polarity switch settings

Fixture is on but there is

Make sure you have the correct audio mode on the control switches.

no movement to the audio

If audio provided via ¼” jack, make sure a live audio signal exists

Adjust sound sensitivity knob

Lamps cuts off

Possible bad lamp or fixture is overheating.

sporadically

Lamp may be at end of its life.

Light will not come on after

Some discharge lamps require a cooling off period before the

power failure

electronics in the fixture can kick start it again, wait 5 to 10 minutes

before powering up

Loss of signal

Use only DMX cables

Install terminator

Note: Keep DMX cables separated from power cables or black lights.

Motor movements are

Possible bad motor driver or sensors

jerky or jumpy

Check polarity switch on controller

Moves slow

Check 220/110v switch for proper setting

No flash

Re-install bulb, may have shifted in shipping

No light output

Check slip ring & brushes for contact

Install bulb

Call service technician

Relay will not work

Check reset switch

Check cable connections

Remote does not work

Make sure connector is firmly connected to device

Stand alone mode

All Chauvet lighting fixtures featuring stand-alone functions do not

require additional settings, simply power the fixture and it will

automatically enter into this mode

Unit wobbles when rotating

Check for damages possibly incurred during shipping

Technical Specifications

WEIGHT & DIMENSIONS

Length ...............................................................

210 mm (8.25 in)

Width ................................................................

194 mm (7.65 in)

Height .................................................................

70 mm (2.75 in)

Weight ..................................................................

2.3 Kg (5 lbs)

POWER

AC Input ...............................................

Autoswitching 100V-240V 50/60 Hz

AC input ...............................................

removable 3-prong IEC 60320 C14

AC outputs ..................................................

(8) NEMA 5-15R receptacles

AC output .........................................................

5A/Channel, Max 15A

CONTROL & PROGRAMMING

Data input..................................................

locking 3-pin XLR male socket

Data output ...............................................

locking 3-pin XLR female socket

Data pin configuration.........................................

pin 1 shield, pin 2 (-), pin 3 (+)

Protocols ..............................................................

DMX-512 USITT

DMX Channels (Mode CH:04) .........................................................

4

DMX Channels (Mode CH:02) .........................................................

2

DMX Channels (Mode CH:01) .........................................................

1

ORDERING INFORMATION

Dimmer/Relay Pack ..............................................................

DMX4

Fuse 10A...............................................................

P170FUSE010

Fuse 6.3A ..............................................................

P170FUSE007

To continue the download you need to go through the captcha:

Chauvet Obey 40 Dmx Controller


Select a Brand

Passion for lighting and the drive to excel

Chauvet is a major innovator, developer and manufacturer, leading the entertainment lighting market in terms of design, flexibility and options.

Chauvet has five brands CHAUVET Professional, CHAUVET DJ, ILUMINARC, TRUSST and ChamSys. Sold through a worldwide network of professional dealers and distributors, all brands have a global reach built upon three core tenets: Value, Innovation, and Performance—VIP for short.

CHAUVET Professional offers innovative professional lighting fixtures for the production and touring market as well as permanent installations.

CHAUVET DJ is a premier line of entertainment lighting, controllers and accessories for the mobile performer, DJs, clubs, corporate events and more.

Trusst is a trussing manufacturer and a brand of Chauvet, specializing in efficient and economical trussing and related components.

Chauvet Dmx Controller

Iluminarc is an architectural lighting company specializing in efficient dynamic lighting, including linear, pod and panel luminaires and control.

Based in the UK, ChamSys Ltd. offers lighting consoles that set industry standards for controllers utilized in the most prominent productions and tours.

About Us

What Is Dmx Controller

Chauvet is a major innovator, developer and manufacturer, leading the entertainment lighting market in terms of design, flexibility and options.

Chauvet has five brands: CHAUVET Professional, CHAUVET DJ, ILUMINARC, TRUSST and ChamSys. Sold through a worldwide network of professional dealers and distributors, all brands have a global reach built upon three core tenets: Value, Innovation, and Performance—VIP for short.

Dmx Controller Manual

A passion for lighting and the drive to excel unite an otherwise diverse staff in South Florida, California, Mexico, United Kingdom, Belgium, France and Germany. All share the realization that straightforward advice, after-sale service and support—going beyond top-of-the line products—are key to a truly satisfied customer.